| Virginia. State Corporation Commission - 1913 - 640 páginas
...test pressure of not less than 40 pounds per square inch, sustained for not less than 5 minutes. 5. When filled with water to 98 per cent, of its capacity...also be capable of standing without leakage a test drop on its chine from a height of 4 feet upon a solid concrete foundation. 6. Bungs and other openings... | |
| 1914 - 844 páginas
...test pressure of not less than 40 pounds per square inch, sustained for not less than five minutes. 5. When filled with water to 98 per cent of its capacity,...also be capable of standing without leakage a test drop on its chime for a height of 4 feet upon a solid concrete foundation. 6. Bungs and other openings... | |
| Virginia. State Corporation Commission - 1914 - 714 páginas
...test pressure of not less than 41) pounds per square inch, sustained for not less than 5 minutes. 5. When filled with water to 98 per cent, of its capacity...barrel or drum must also be capable of standing without leaking a test drop on its chine from a height of 4 feet upon a solid concrete foundation. 6. Bungs... | |
| George Arthur Burrell, Frank Meyers Seibert, George G. Oberfell - 1915 - 122 páginas
...test pressure of not less than 40 pounds per square inch, sustained for not less than five minutes. 5. When filled with water to 98 per cent of its capacity,...also be capable of standing without leakage a test drop on its chime for a height of 4 feet upon a solid concrete foundation. 6. Bungs and other openings... | |
| Raymond Foss Bacon, William Allen Hamor - 1916 - 470 páginas
...hydrostatic test pressure of not less than 40 Ib. per square inch, sustained for not less than 5 min. 5. When filled with water to 98 per cent. of its capacity,...also be capable of standing without leakage a test drop on its chime for a height of 4 ft. upon a solid concrete foundation. Bureau for the Safe Transportation... | |
| Raymond Foss Bacon, William Allen Hamor - 1916 - 466 páginas
...not less than 40 Ib. per square inch, sustained for not less than 5 min. 5. When filled with water'to 98 per cent. of its capacity, the type of barrel or...also be capable of standing without leakage a test drop on its chime for a height of 4 ft. upon a solid concrete foundation. 6. Bungs and other openings... | |
| RAYMOND FOSS BACON, PH.D., WILLIAM ALLEN HAMOR, M.A. - 1916 - 464 páginas
...hydrostatic test pressure of not less than 40 Ib. per square inch, sustained for not less than 5 min. 5. When filled with water to 98 per cent, of its capacity, the type of barrel o- drum must also be capable of standing without leakage a test drop on its chime for a height of 4... | |
| Georg Lunge - 1924 - 438 páginas
...test pressure of not less than 40 Ib. per square inch, sustained for not less than five minutes. 9. When filled with water to 98 per cent. of its capacity,...dropping it diagonally on its chime from a height of 6 ft. upon a solid concrete foundation. 10. Factory tests of the type package to insure that the product... | |
| F. Hirsch - 1926 - 152 páginas
...deformation, and without leaking, a hydrostatic test pressure of not less than 40 Ib. per square inch. (b) When filled with water to 98 per cent, of its capacity...also be capable of standing without leakage a test drop on its chime from a height of 4 feet upon a solid concrete foundation. The method of manufacturing... | |
| Virginia. State Corporation Commission - 1927 - 396 páginas
...pounds per square inch, sustained for not less than 5 minutes. 5. When filled with water to 98 percent of its capacity the type of barrel or drum must also be capable of standing without leaking, a test drop on its chine from a height of 4 feet upon a solid concrete foundation. 6. Bungs... | |
| |